1
. .
FD-302 (Rev. 10-6-95)
Investigation on 10/08/2002 a Fort Detrick, Maryland
File # 279A-WF-22 QS Date dictated
QA-WF-222936 SUB] _—_—«|{ 302% ate dictated =N/A
by
This document contains neither recommendations nor conclusions of the FBI. It is the property of the FBI and is loaned to your agency;
it and its contents are not to be distributed outside your agency.
REIN IS UNCLASSIFIED
. . ALL INFORMATION CONTAINED
) DATE l2-20-2008 BY 60324 uc baw/re/mjs
-1-
FEDERAL BUREAU OF INVESTIGATION
Date of transcription 10/10/2002
On October 8, 2002,[_——sds was interviewed at[__] be
place of employment, the United States Army Medical Research bic
Institute of Infectious Dise (USAMRIID), Fort Detrick
Maryland telephone by_Special Agent
Co ret, and Postal Inspector After being
advised of the identity of the agents and the purpose of the
interview,[ __|provided the following information:
was provided with a copy of the second floor plan
with three freezers drawn in the hallway outside
The floor plan is contained in the 1A envelope with
subsequent notations using red ink for pre-renovation and
lack ink for post-renovation respectively, as well as notations
indicating the location _of certain features of the first floor and
basement in Building
for Buildin
TO
advised that the three freezers are still in the D6
same location indicated on the floor plan, however these are_new b7
freezers that hold the same contents as the previous ones.
further advised that these freezers were obtained prior to the
departure of from USAMRIID. The freezers are
kept at -70° Celsius and are equipped with an alarm that sounds if
the door is kept open long enough for the temperature to rise.
After the alarm sounds and the door is closed, it is difficult to
reopen the door. This is because of a strong vacuum seal that
develops until the temperature returns to normal.
[___] thought that the freezers may have had locks in
place during the time that[ | was employed at USAMRIID,
however these locks may not have been used. The freezers may also
have all had the same generic lock that everyone had the key for.
There are new locks on these freezers that were installed
approximately two to three weeks ago, however they are not very
sturdy as they must be glued rather than bolted to the exterior of
the freezer in order to preserve the freezer's structural
integrity.
During the renovations of Building | ign thel _—si bé
1990sP ving bIC
that time their freezers were kept on the _
Ve
ma)
omen
1
Q
SA
Community corrections
No user corrections yet.
Comments
No comments on this document yet.
Bottom Reader Ad Slot
Bottom Reader Ad Slot placeholder
If you would like to support SpookStack without paying out of pocket, please consider allowing advertising cookies. It helps cover hosting costs and keeps the archive free to browse. You can change this choice at any time.
Continue Exploring
Reader
Topic
Agency Collection
Explore This Archive Cluster
Broad Topic Hub
Topic Hub
investigation
Related subtopics
Subtopic
Subtopic
Subtopic
Subtopic
Subtopic
Subtopic